Company Name
Hollyx Co., Ltd.
Representative
President/CEO Kikuji Horiuchi
Foundation
May 28, 1962
Establishment
April 1, 1997
Capital
15 million yen
Office Address
294-46 Ashitaka, Numazu, Shizuoka 410-0001
TEL.055-925-4601(main) FAX.055-925-4603
E-mail:kikuji@hollyx.co.jp
URL:http://www.hollyx.co.jp/
Employees
12
Main Banks
The Shizuoka Bank, Shimotogari branch office
The Bank of Tokyo-Mitsubishi UFJ, Ltd,
Numazu branch office
Business Description
Manufacturing and marketing of medical devices, orthopaedic implants, surgical instruments
Sales/manufacture business of medical devices (License NumberF22B1X00009)
Manufacture business of medical devices
(License NumberF22BZ005029)
Sales/lease business of medical devices
(License NumberFToho A No.11-15)
Repair service business of medical devices
(License NumberF22BS200021)
May, 1962

President, Kikuji Horiuchi founded Horiuchi Medical Engineering Co., Ltd. in Kawaguchi City, Saitama prefecture in Japan.
It was the first company to develop and manufacture artificial joint prosthesis's in Japan. Its main products included surgical instruments.

iDeveloped productsj
œArtificial hip jointF Katayama type, Maezawa type and Itami type from the Jikei University School of Medicine
œArtificial knee jointFKatayama type, Nishi type, Kudo type and Yoshino type from the Jikei University School of Medicine
œArtificial shoulder jointFKatayama type and Nishi type from the Jikei University School of Medicine
œArtificial elbow jointFKatayama type, Nishi type, Imura type and Kudo type from the Jikei University School of Medicine
œArtificial ankle jointFOtuka-Uchida type from Tokyo Metropolitan University and Nara Medical University type
In addition, medical implants including bone fixation devices were researched and developed.
August, 1984
Horiuchi joined Zimmer Japan KK (present Zimmer KK).
Horiuchi, in senior manager position, developed the artificial joint/CHS plates/MTS system.

He dedicated 14 years to the establishment of the Development/Manufacturing Department and formulated its foundation and subsequent growth.
April, 1997
Moved to the Numazu Business Incubation Center supported by the New Business Development Office, the Department of Commerce, Industry and Labor, Shizuoka Prefecture and established Hollyx Co., Ltd.
œArtificial joints, bone fixation devices (plates, screws, intramedullary nails etc.) were researched and developed.
July, 1997
œApproved by the prefectural governor under the Temporary Law concerning Measures for the Promotion of the Creative Business Activities of Small and Medium Enterprises.
œTi-CHS Plate System
Marketing approval number 20900BZZ00812000 obtained under the Pharmaceutical Affairs Law of Japan.
July, 1999
œHollyx Spinal Fixation System I
Marketing approval number 21100BZZ00457000 obtained under the Pharmaceutical Affairs Law of Japan.
œBone Fixation System
Marketing approval number 21100BZZ00465000 obtained under the Pharmaceutical Affairs Law of Japan.
September, 1999
œMorgan Pin System
Marketing approval number 21100BZZ00590000 obtained under the Pharmaceutical Affairs Law of Japan.
May, 2000
œHollyx Plate System I
Marketing approval number 21200BZZ00247000 obtained under the Pharmaceutical Affairs Law of Japan.
œHollyx Bone Fixation System 2
Marketing approval number 21200BZZ00343000 obtained under the Pharmaceutical Affairs Law of Japan.
October, 2000
œA US patent issued for Free Lock System
United States Patent (Patent NumberF6139552)
February, 2001
œHollyx CHS Plate System 2
Marketing approval number 21300BZZ00044000 obtained under the Pharmaceutical Affairs Law of Japan.
October, 2001
œTi-CHS USP Tube Plate System
Marketing approval number 21300BZZ00416000 obtained under the Pharmaceutical Affairs Law of Japan.
œNew Head Office constructed in Ashitaka, Numazu city.
2002
œHollyx Femoral Neck Intramedullary Nail System
Marketing approval number 21400BZZ00526000 obtained under the Pharmaceutical Affairs Law of Japan.
œCannulated Cancerous Screw BST
Marketing approval number 21400BZZ00527000 obtained under the Pharmaceutical Affairs Law of Japan.
2003
œGranted the Award for Scientific and Technical Achievement by Shizuoka prefecture
œEpiphysis Plate System I
Marketing approval number 21500BZZ00046000 obtained under the Pharmaceutical Affairs Law of Japan.
œMillennium Circular Fixation S
Marketing approval number 21500BZZ00162000 obtained under the Pharmaceutical Affairs Law of Japan.
œMillennium Circular Fixation M
Marketing approval number 21500BZZ00163000 obtained under the Pharmaceutical Affairs Law of Japan.
œART System
Marketing approval number 21500BZZ00197000 obtained under the Pharmaceutical Affairs Law of Japan.
œHollyx Femoral Neck Intramedullary Nail W
Marketing approval number 21500BZZ00258000 obtained under the Pharmaceutical Affairs Law of Japan.
œOmnibus System
Marketing approval number 21500BZZ00350000 obtained under the Pharmaceutical Affairs Law of Japan.
œTiming Screw System
Marketing approval number 21500BZZ00520000 obtained under the Pharmaceutical Affairs Law of Japan.
2004
œReceived gthe 13th Shizuoka Prefectural New Business Awardh
œA clean room facility completed
œClavicle Epiphysis Plate System
Marketing approval number 21600BZZ00190000 obtained under the Pharmaceutical Affairs Law of Japan.
œParasol Screw System
Marketing approval number 21600BZZ00510000 obtained under the Pharmaceutical Affairs Law of Japan.
œInnocent Plate System type SP
Marketing approval number 21600BZZ00623000 obtained under the Pharmaceutical Affairs Law of Japan.
œInnocent Plate System type L
Marketing approval number 21600BZZ00624000 obtained under the Pharmaceutical Affairs Law of Japan.
œInnocent Plate System type T
Marketing approval number 21600BZZ00625000 obtained under the Pharmaceutical Affairs Law of Japan.
2005
œTi-Edge System(supplied sterile)
Marketing approval number 21700BZZ00182000 obtained under the Pharmaceutical Affairs Law of Japan.
œPalmer Radial System
Marketing approval number 21700BZZ00357000 obtained under the Pharmaceutical Affairs Law of Japan.
œDual S.C. Screw System
Marketing approval number 21700BZZ00374000 obtained under the Pharmaceutical Affairs Law of Japan.
2006
œCross- Trochanteric Compression Nail System
Marketing approval number 21800BZZ10028000 obtained under the Pharmaceutical Affairs Law of Japan.
2007
œHollyx earned an honor as one of "300 of Japan's Vibrant Monodzukuri (Manufacturing) SMEs" selected by Small and Medium Enterprise Agency, Ministry of Economy, Trade and Industry.